Application:Overhead
Jacket:No sheath, Without
Product name:ACSR Cable
Conductor:Aluminium Conductor Steel Reinforced
Color:Silver white
Standard:GB1179, IEC 1089, DIN 48204, ASTM B232, BS215
Aluminium Conductor AAC AAAC ACSR ACAR ACSS/TW ABC Power cable Construction:
1.Conductor (both phase and Neutral)
The conductors shall be of aluminum 1350 wires and compacted circular stranded ;
2.Insulation:
The conductors shall be extruded with XLPE as insulation ,each phases is marked with numbers and letters ,
1 ONE,2 TWO,3 THREE or with one rib,two ribs or three ribs to denote the phases.The neutral core carries equally space ribs right round the circumference
3.Assembly
The Core shall be laid up with a left hand Lay.
Type |
Description |
AAC |
All Aluminum Conductor |
ACSR |
Aluminum Conductor Steel Reinforced |
AAAC |
All aluminum Alloy Conductor |
ACAR |
Aluminum Conductor Alloy Reinforced |
AACSR |
All Aluminum Alloy Conductor Steel Reinforced |
ACSR / AW |
Aluminum Conductor Aluminum Clad Steel Reinforced |
TACSR |
Thermal Resistant Aluminum-alloy Conductor Steel Reinforced |
ACSS |
Aluminum Conductor Steel Supported |
ACSS/AW |
Aluminum Conductor. Aluminum-Clad Steel Supported |
ACSS/TS |
Aluminum Conductor, Steel Supported. Trapezoidal Shaped |
ACS |
Aluminum Clad Steel |
CCS |
Copper Clad Steel |
GSW |
Galvanized Steel Wire |
BCC |
Bare copper stranded conductor (Hard Drawn) |
Greased conductor |
Anti-corrosive stranded conductor |
Technical Parameters:
The technical data of Aluminium Conductor AAC AAAC ACSR ACAR ACSS/TW ABC Power cable power wire astm b232 acsr overhead conductor as below for reference,any customized is available.
IEC 61089Standard
Application :
AAC AAAC ACSR Aluminum Power cable as a new-type aerial cable is used for transmitting electric power overhead,
extensively used in rebuilding of urban and forest region electrified wire nttting.
It improves the safety and reliance of electrified wire netting.
Applications of bare conductor | To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600volts or lower at a conductor temperature of 75°C maximum. | ||||||||
Applications of bare conductor | To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a
conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. |
||||||||
Applications of bare conductor | Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service
entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors |
1.UNDERSTAND CUSTOMER NEEDS
Q:I didn’t find the cable which I need in this page?
Welcome to contact us Whatsapp:+86-13891913198 WeChat:13891913198 Mob: +86-13891913198 Email:Penn@sxjshsm.com Add: Sanqiao Street Xixian New District, Xian,Shaanxi,China
+86 13891918380